It is designed for longer life. Proven flight design ensures a perfect distribution of material to be dried. The drum is guided through two rolling steel rings on 4 trunion rollers, coupled with geared motors and bearings, mounted on a sturdy main frame.
Our modulating burner works with either diesel or heavy oil. Burner is provided with servo motor for air regulation and PID Controller for modulation.
It is fully automatic and guarantees best product quality. The operator can choose all the required process parameters and all components of the tower will become automatically set to obtain the requested product. The main units of the tower such as elevator, screen, hot aggregate storage bins and mixer are designed for long life, low maintenance and reliability.
Plants are provided with abrasion resistant and heavy duty cold feed bins. Bins have self-relieving bottom opening, which eliminates bridging of the feeders. Each bin is provided with variable speed inverter drive through geared motor.
Computerised Controls are provided for burner, temperature, damper, emergency plant shut down, sequential start and stop, etc. The display shows Aggregate, Asphalt, Filler and Production TPH along with temperature display of Aggregate, Asphalt, Exhaust and Mix Material. Daily production data can be printed out for records. All controls are mounted on a centralised control panel inside the control room.
Bag house filters remove the dust from the dryer’s exhaust and comply with the most severe environmental regulations. They are fitted with safety devices for temperature control and automatic counter-flow cleaning through main exhauster and complete system for recovery and re-use of filler.